Click Here to go to our main page.

Your Source For Solid Solutions To Complicated Ground Conditions
Site Map Search Contact Us Featured Projects Services

Back Up Next

Auger Cast-In-Place Piles

 

 

 

 

Temporary shoring at existing column locations for pit excavation.

Greenville, NC

 

General Contractor:

Miller Building

 

12" diameter piles x 20' depth were installed as temporary shoring for a new press pit at a manufacturing facility. Auger cast-in-place piles were also installed to support the new press. Piles were drilled and installed in 33' of headroom.

Back Up Next

Home Site Map Search Contact Us Featured Projects Services
 
Technical Foundations, Incorporated
P.O. Box 50282 w Richmond, VA  23250 w (804) 328-4500 w fax: (804) 328-4510
Copyright © 2007 Technical Foundations, Inc.
Last modified: June 19, 2007